Sample reports

Public examples are available without an account. Each report has print and PDF download controls.

2 rows from 1 buildings. The README sheet carries the framework notice.

EnergyLens — Regulatory Check — Germany

Musterhaus (fictional example)

Berlin · Germany

Report type
Regulatory Check — Germany
Methodology version
1.0.0
Generated
—
Prepared by
Ali Mert Özdemir, B.Sc. Energy Systems Engineering, M.Sc. Energy Management (in progress)
Data quality: High

Fictional example with invented inputs, for illustration only.

1.Inputs

Employees: n/a — not entered · turnover: n/a — not entered · planned replacement: n/a — not entered

2.Checklist

TopicStatusReasonSource
CO2KostAufG (incl. GModG 50/50 rule from 2028)AppliesResidential stage; landlord share 40%. Heaters installed after 2026-07-29: 50/50 split from 2028-01-01.GModG and CO2KostAufG
GModG heating rules and Bio-Treppe (planned heater replacement)Not determinedNo planned heater replacement year entered.GModG; Görg overview
Energieausweis obligation on sale or lettingAppliesOn sale, letting or leasing an Energieausweis must be presented; only authorised issuers may prepare it. Building is let; required on new letting.GModG / GEG Energieausweis provisions
Non-residential classes A–G (from 2027) and minimum performance 2030/2033 (information)Does not applyResidential building.GModG; Gewerbepass summary
CSRD applicabilityNot determinedCompany employees and net turnover not entered.EU Omnibus I, Council adoption summary
Building data for ESRS (E1-5, E1-6)Data availableE1-5: Natural gas 150.0 MWh; Electricity 6.0 MWh. E1-6: Scope 1 27.3 t CO₂, Scope 2 location-based 2.1 t CO₂ (2025). E1-6 intensity is per net revenue and must be computed by the reporting company.ESRS E1 (Delegated Regulation (EU) 2023/2772)
EnEfG / EDL-G company obligationsNot determinedDepend on total company energy use — not assessed.EnEfG; EDL-G; EU Taxonomy Regulation; SFDR
EU Taxonomy and SFDRNot determinedNot assessed.EnEfG; EDL-G; EU Taxonomy Regulation; SFDR

3.Data quality and limitations

Rating: High — All carriers have complete records, stated area and fuel bases, costs and required supplier factors.

Statuses are screening indications from the entered data, not legal advice. Verify the promulgated statutes and individual exemptions with qualified professionals. An Energieausweis may only be issued by authorised issuers.

4.Assumptions and sources

ItemValueTypeSource
Area (Wohnfläche)900 m²fictional inputEnergyLens fictional example (invented inputs)
Natural gas consumption 2025150,000 kWh Hsfictional inputEnergyLens fictional example (invented inputs)
Natural gas CO₂ factor0.182 kg CO₂/kWhpublic referenceEBeV 2030, Anlage 2
Electricity consumption 20256,000 kWhfictional inputEnergyLens fictional example (invented inputs)
Electricity CO₂ factor0.344 kg CO₂/kWhpublic referenceUmweltbundesamt (UBA), German electricity mix
Grid factor projection2025: 0.344 → 2030: 0.150 → 2045: 0.020 kg CO₂/kWhEnergyLens assumptionEnergyLens assumption (no external source)
KSG building-sector reference2020: 118 → 2030: 67 Mt/year (statutory sector greenhouse-gas reference, not building CO₂)public referenceKSG Anlage 2a; KSG §3 for assumed post-2030 end point
BEHG CO₂ prices2021–2027: 2021 €25 · 2022 €30 · 2023 €30 · 2024 €45 · 2025 €55 · 2026 €60 · 2027 €60 €/t CO₂ netpublic referenceBEHG; German Bundestag notice for 2027
ETS2 price scenarios2028–2035: low 60–60 · central 90–110–140 · high 130–160–210 €/t CO₂ netEnergyLens assumptionEnergyLens assumption (no external source)
CO2KostAufG residential stages<12 kg CO₂/m² Wohnfläche/year: 0% · <17 kg CO₂/m² Wohnfläche/year: 10% · <22 kg CO₂/m² Wohnfläche/year: 20% · <27 kg CO₂/m² Wohnfläche/year: 30% · <32 kg CO₂/m² Wohnfläche/year: 40% · <37 kg CO₂/m² Wohnfläche/year: 50% · <42 kg CO₂/m² Wohnfläche/year: 60% · <47 kg CO₂/m² Wohnfläche/year: 70% · <52 kg CO₂/m² Wohnfläche/year: 80% · ≥52 kg CO₂/m² Wohnfläche/year: 95%public referenceCO2KostAufG
Boiler efficiencyCondensing gas 0.95; older gas 0.85; unknown gas 0.9 (Hi basis)EnergyLens assumptionEnergyLens assumption (no external source)
Heat-pump SCOPCentral 3; sensitivity 2.5 and 3.5 (seasonal coefficient of performance)EnergyLens assumptionEnergyLens assumption (no external source)
PV specific yield900 kWh/kWp/year (range 850–1050 kWh/kWp/year)EnergyLens assumptionEnergyLens assumption (no external source)
Finance inputs5% discount rate; 20 years; 0%/year price escalationEnergyLens assumptionEnergyLens assumption (no external source)

This report is an automated desk-based screening based on data supplied by the client and on public reference values. It is not an energy audit under DIN EN 16247 or EDL-G, not an Energieausweis under GModG, not an Energieberatung eligible for BAFA/KfW funding, and not legal, tax, valuation or investment advice. All figures are indicative. Subsidy eligibility, costs and savings must be verified by qualified professionals before any decision. EnergyLens is not affiliated with GRESB or any public authority.

Methodology 1.0.0 · generated — · prepared by Ali Mert Özdemir, B.Sc. Energy Systems Engineering, M.Sc. Energy Management (in progress)